Commonly used in:
-
Hotel
-
Industrial
-
Institutional
-
Office
-
Retail
Chiller
Carrier Aquaforce® 30XW Chiller
The 30XW units are high-efficiency, indoor water-cooled chillers with a quiet, low-vibration design featuring screw compressors.
- AHRI certified efficiencies to 0.468 kW per ton IPLV
- Chlorine-free R-134a HFC refrigerant
- Low energy consumption during part load and full load operation
- Available operational voltages include: 200-v, 230-v, 380-v, 460-v, 575-v (60 Hz)
Features & Specifications
You are viewing the product features & specifications for the Carrier Aquaforce 30XW Chiller
Performance Features
- AHRI certified efficiencies to 0.468 kW per ton IPLV
- Chlorine-free R-134a HFC refrigerant
- Low energy consumption during part load and full load operation
- Available operational voltages include: 200-v, 230-v, 380-v, 460-v, 575-v (60 Hz)
- Wye-delta starter is standard on 200-v and 230-v units (factory-installed option for all other units)
- Leaving-fluid temperature directly controlled to within 0.5°F (0.3°C)
- Entering-fluid temperature continuously monitored to detect flow or load changes
- Compatible with Carrier Comfort Network® (CCN) communication link
- ASHRAE 90.1 compliant
- Certified in accordance with AHRI Standard 550/590
- Heat recovery capability up to 140°F (60°C)
Reliability Features
- Dual independent refrigeration circuits (sizes 325-400)
- Low voltage control circuits
- Short cycle protection
- Dual chiller control
- Temperature reset from return fluid
- Chilled water flow switch
- Electronic refrigerant gauges
- Listed with UL and UL, Canada
Maintenance Features
- Hermetic twin screw compressors
- Mechanically cleanable condenser and evaporator
- Alarm contacts
- Filter drier
- Moisture indicating sight glass
- Accessible service information including suction and discharge pressure and temperature using Navigator™ display module (factory-installed option or field-installed accessory)
- ON/OFF control switch
Installation Features
- Unit width of 48 in. or less
- Single point electrical connection (with optional control power transformer)
- Heat mode controls standard
Factory-Installed Options
- Wye-delta start
- Dual point power connection (325-400 ton)
- Non-fused disconnect
- Control power transformer
- 115-v GFCI (ground fault circuit interrupter) convenience outlet
- Marine water boxes
- Flange connections
- Suction service valves
- Isolation valves
- One-pass evaporator water box
- Three-pass evaporator water box
- 300 psi (2068 kPA) water side operating pressure rating
- One-pass condenser water box
- Minimum load control
- Navigator display module
- LON (Local Operating Network) translator control
- BACnet Communication
- EMM (Energy Management Module)
- Standard water-side operating pressure of 150 psig (1034 kPa) with an available option of 300 psig (2068 kPa)
- Discharge and liquid line shutoff valves
Field-Installed Accessories
- Temperature reset sensor
- EMM
- LON translator control
- BACnet translator control
- Sound Attenuation Packages
- Navigator display module
- Neoprene vibration isolation pads
- Vibration isolation springs
30XW Unit Size | Capacity | Input Power (kW) | Evaporator Flow | Evaporator Pressure Drop | Condenser Flow | Condenser Pressure Drop | |||||
---|---|---|---|---|---|---|---|---|---|---|---|
Tons | Output (kW) | gpm | L/s | Ft of Water | kPa | gpm | L/s | Ft of Water | kPa | ||
150 | 160.2 | 563.3 | 104.7 | 383.1 | 24.2 | 11.1 | 33.2 | 491.4 | 31 | 14.7 | 43.9 |
175 | 170.2 | 598.4 | 110.2 | 407 | 25.7 | 12.4 | 37.1 | 521.3 | 32.9 | 16.4 | 49 |
185 | 178.2 | 627.3 | 119.7 | 426.8 | 26.9 | 13.5 | 40.4 | 549.6 | 34.7 | 18.1 | 51.4 |
200 | 191.2 | 672.3 | 123.6 | 457.4 | 28.9 | 15.3 | 45.7 | 585.6 | 36.9 | 20.3 | 60.7 |
225 | 222.8 | 783.4 | 146.5 | 532.9 | 33.6 | 12 | 35.9 | 684.1 | 43.2 | 14.9 | 44.5 |
250 | 241.2 | 848.1 | 151.6 | 577 | 36.4 | 13.8 | 41.2 | 735.6 | 46.4 | 17 | 53.2 |
260 | 245.1 | 861.8 | 165.2 | 586.2 | 37 | 14.2 | 42.4 | 755.4 | 47.7 | 17.8 | 50.8 |
275 | 262.9 | 924.4 | 167.9 | 628.9 | 39.7 | 16.2 | 48.4 | 803.6 | 50.7 | 20 | 59.8 |
300 | 285.7 | 1004.5 | 183.9 | 683.2 | 43.1 | 18.8 | 56.2 | 875.3 | 55.2 | 23.3 | 69.6 |
325 | 322.5 | 1133.9 | 204.4 | 771.2 | 48.7 | 15.5 | 46.3 | 984.5 | 62.1 | 11.8 | 35.3 |
350 | 343.2 | 1206.7 | 216.3 | 820.9 | 51.8 | 17.3 | 51.7 | 1047 | 66.1 | 13.3 | 39.8 |
375 | 364.6 | 1281.9 | 236 | 872 | 55 | 19.4 | 58 | 1117 | 70.5 | 15 | 44.8 |
400 | 385.2 | 1354.4 | 242.4 | 921.4 | 58.1 | 21.4 | 64 | 1175 | 74.1 | 16.5 | 49.3 |
30XW Unit Size | Full Load Efficiency (kW/Ton) | IPLV (kw/Ton) |
---|---|---|
150 | 0.6537 | 0.5399 |
175 | 0.6477 | 0.5379 |
185 | 0.671 | 0.5454 |
200 | 0.6462 | 0.5389 |
225 | 0.6576 | 0.5358 |
250 | 0.6284 | 0.5248 |
260 | 0.6739 | 0.5451 |
275 | 0.6384 | 0.5329 |
300 | 0.6439 | 0.5383 |
325 | 0.6338 | 0.4724 |
350 | 0.6303 | 0.4716 |
375 | 0.6473 | 0.4757 |
400 | 0.6293 | 0.4723 |
AHRI = Air Conditioning, Heating and Refrigeration Institute
IPLV = Integrated Part Load Value
NOTES
1. Rated in accordance with AHRI Standard 550/590 at standard rating conditions.
2. Standard rating conditions are as follows:
Cooler Conditions:
Leaving Water Temperature: 44°F (6.7°C)
Flow: 2.4gpm per ton (0.043 L/s per kW)
Condenser Conditions:
Entering Water Temperature: 85°F (29.4°C)
Flow: 3.0gpm per ton (0.054 L/s per kW)
Fouling Factor (Cooler):
0.00010 hr x sq ft x °F per Btuh (0.000018m2 x K per W)
Fouling Factor (Condenser):
0.00025 hr x sq ft x °F per Btuh (0.000044m2 x K per W)
3. IPLV is a single number part load efficiency value calculated from using the efficiency values at 100%, 75%, 50%, and 25% of load when the chiller is operating in AHRI conditions.
4. All data in the above table was generated in Packaged Chiller Builder version 3.29. Please refer to the most current version of the Packaged Chiller Builder for the most up-to-date data.
5. Contact Carrier for custom ratings.
Learn from our Client Testimonials
-
Alstra (formerly known as Concepcion-Building and Industrial Solution) has been a valued partner at Park Terraces. I have personally witnessed the way they work and I am very happy with the products and the level of service they provide.
Cherryl Uy
Area Head - Central Projects
Project Development Group
Ayala Land Premier
-
One vital aspects in residential building operations is to have air conditioned lobbies that exceed cooling expectations of our residents. Carrier provided us with efficient, reliable and low operating costs air conditioners that made us confident in providing cooling comfort which met our residents need.
Jovan Barargo
Building Manager
Edades Tower & Proscenium at Rockwell
-
Partnering with Alstra, formerly Concepcion-Building & Industrial Solutions, is a strategic move that has helped us not only in managing better the cooling requirement of our branches but in keeping our expenses low as well. The 3 & 5 TR inverter, floor-mounted & ceiling cassette units are key to us providing an office conducive to do business transactions; keeping both our clients & employees happy.
Ma. Kathleen S. Aquino
Team Head
Supply Chain Management Division
Bank of the Philippine Islands
-
We have no issue with the timeliness in terms of deliverables, equipment supply and installation, which was duly met as committed. Their on-site team executed quality workmanship.
Alvin Olanday
Project Director
Makati Development Corporation
-
The indoor units, which range from cassettes, wall hung and ceiling types, were well designed and very well installed. We are very happy with the supply work of Alstra (formerly known as Concepcion-Building and Industrial Solution) and look forward to a continued business relationship as partners for the DLSZ Air Conditioning System.
Mr. Charles Rapaport
Project Head
Dela Salle Santiago Zobel-
Vermosa Campus
Support 24/7
- Ready to cater to your every need
- Ask a question
Tried. Tested. Trusted
- Our rigorous tests and original parts ensure excellent quality
Carrier Authorized
- Our skilled technicians undergo extensive training so your unit is in good hands
- Visit Customer Care
Tell us about your Carrier Aquaforce® 30XW Chiller
How would you rate this product?